Pspice edit simulation profile. Pspice Simulation 2019-07-26

Pspice edit simulation profile Rating: 8,5/10 1293 reviews

OrCAD Tutorial Simulating The Circuit

pspice edit simulation profile

This will be covered in more detail in the Model Editor chapter. The Mark Label icon, rightmost icon shown above, can be used to display the cursor value on the Probe display. I took this class for the convenience Until I get back home. Voltage differential markers are always placed in pairs. Parts can be deselected and selected either from the master design or from the created test benches. But I can imagine the problem is that the process trying to display the page has not inherritted the correct permisions to access the file. The other option is the Gaussian distribution, which is the familiar bell-shaped curve commonly used in manufacturing.

Next

PSPICE Libraries Help

pspice edit simulation profile

Maybe Cadence could offer some guidance - now that my experience is not a single random report. The three bias point analysis simulation profiles that have been created are listed in the Project Manager Fig. All the components in all the schematics in the Test Bench folder are grayed out. If you want to save data from the third, fifth, seventh and tenth run, select Runs list and enter 3, 5, 7, 10 in the runs box. Transmittance data of the non-implanted and implanted glasses are presented in Fig. To change the value you can double-click the visible value and enter the correct value into the Display Properties dialog box that opens. Followed to nonsymmetrical profile of implanted ions, the size distribution of metal nanoparticles in dielectrics in the depth are also not symmetrical.

Next

Pspice Simulation

pspice edit simulation profile

The temperature will be swept from 0°C to 50°C in 1°C increments. But the Simulations Settings window is blank - totally white space with a boarder. I bought the non light version and installed this in place of the lite version. The maximum number of waveforms that can be displayed in Probe is 400. If you want to save data from the first three runs, select First and then enter 3 in the runs box. To add an axis choose Plot - Add Y Axis. When a test bench is created, a Test Bench folder, which contains all the design schematics is added to the bottom of the Project Manager.

Next

Simulation Profiles not displaying in Orcard Capture CIS Lite

pspice edit simulation profile

Try opening SimSetup dialog and see if this works. A new axis will be added to the right of the existing axis and will be designated as the active axis. The active axis will be the one to which new traces are added or to which cursors will be applied. The Schematic will have been updated with the values from the Bias Simulation, activate the Capture Schematic window, if it is not already active, to view the schematic. The Name is the reference designator for the voltage source which in this case is V1. The axis for current is the active axis.

Next

Simulation Profile

pspice edit simulation profile

Again, the Probe in the schematic will change from grey to reflect the trace colour. Probe can also perform complex mathematical calculations. If you configure the analysis to sweep a voltage or current source, then the value of the source will be set by the simulation profile during simulation. Having Probe open during a simulation is useful when you want to check the validity of a long simulation early into the run. Luay ok i tried all of these, nothing worked! If you want to use temperature as a swept variable, i. A change in the near-surface layer composition was due to cascade atom mixing in glass and target sputtering.

Next

Pspice Simulation

pspice edit simulation profile

B 206 4 2003 624—628, with permission from Elsevier. . Provide details and share your research! Always check to be sure that options within the Probe Window and Data Collection tabs are configured before running your simulating. This value must be an odd integer number from 1 to 32,767. But I have defined the model in the code. The sweep type is set to Linear, starting from 0 to 10 V in steps of 1 V. For the input stimulus, using the predefined V in sourcestm in Chapter 6 , edit the simulation profile and select the Configuration Files tab, select Category to Stimulus and Browse to the location of the stimulus.

Next

OrCAD Tutorial Simulating The Circuit

pspice edit simulation profile

This option allows you to apply the setup to the new simulation data. You will need to complete before you will be able to work through this section. The first run is the nominal run where no tolerances are applied. It worked fine with me! The Last Plot option allows you to restore the settings from the last probe display but using the new simulation data. This has the advantage of making every possible piece of data available to the Probe Window.

Next

Simulation Profile

pspice edit simulation profile

Transmittance Spectra of the SiO 2 1,2 and Soda-Lime Silicate 3,4 Glasses Before and After Cu-Ion Implantation. If you don't do that, you'll get exactly the symptom you describe. You can specify that the Probe Windowis opened whenever the profile is opened. You can think of it as an electronic oscilloscope. Once that made I went to Draw-Get New Part and finally all the components where there I was able to make a circuit, I run the simulation and it worked perfectly ;D I hope it is useful for you! When users create a test bench, another design folder is created in the project folder.

Next

Pspice Simulation

pspice edit simulation profile

If necessary, use the Pivot button to pivot the Property Editor grid so that the properties are listed at the left-hand side of the tab, this will usually allow all of the Part Properties to be viewed without the need to pan, or scroll, through them. That is, if the first marker is placed on a node that is 10V and the second is placed on a node that is 5V, then the value will be 5V. Note that it is recommended that you simulate the circuit before moving onto physical layout to check that the circuit has been entered correctly. This is useful if you have a complicated Probe display setup such as multiple axes with custom scales and then find that you need to resimulate. I am a new one here, just wanna to help those who met the same problem. In the previous output file, every node is floating because node 0 has not been assigned.

Next

Lesson 3: DC Sweep Analysis

pspice edit simulation profile

I just had to drop one of them I chose the one named special. Use MathJax to format equations. Radiation defects in silicate glasses caused by ion implantation, introduce some absorption in the ultraviolet as it possible to see in short wavelength part of spectra in Fig. This indicates that this is the current or active profile. Note You can rename the reference designator for the voltage source to anything you like as long as the first character is a V. For example, if you are sweeping a source, then Model Name and Model Type become unavailable for editing. For example, the netlist in Fig.

Next